Anybus indicators
PROFIBUS
#
Item
1
Operation Mode
2
Status
3
PROFIBUS Connector
4
M12 Female Connector
5
M12 Male connector
Operation Mode
State
Off
Green
Flashing Green
Flashing Red (1 flash)
Flashing Red (2 flashes)
Status
State
Indication
Off
Not initialized
Green
Initialized
Flashing Green
Initialized, diagnostic
event(s) present
Red
Exception error
28
Indication
Not online / No power
Data exchange
Clear
Parametrization error
PROFIBUS Configuration error
Comments
Anybus state = 'SETUP¨' or
'NW_INIT'
Anybus module has left the
'NW_INIT' state
Extended diagnostic bit is set
Anybus state = 'EXCEPTION'
ProfiNet IP
#
Item
1
Network status LED
2
Module status LED
3
Link/Activity LED
4
Ethernet Interface
Network Status LED
Note: A test sequence is performed on this LED during
startup
LED State
Description
Comments
Off
Offline
- No power
- No connection with IO Controller
Green
Online
- Connection with IO Controller
(RUN)
established
- IO Controller in RUN state
Green,
Online
- Connection with IO Controller
flashing
(STOP)
established
- IO Controller in STOP state
Module Status LED
Note: A test sequence is performed on this LED during
startup
LED State
Description
Off
Not Initialized
Green
Normal
Operation
Green,
Diagnostic
1 flash
Event(s)
Green,
Blink
2 flashes
Red
Exception Error
Red, 1 flash
Configuration
Error
Red,
IP Address Error
2 flashes
Red,
Station Name
3 flashes
Error
Red,
Internal Error
4 flashes
LINK/Activity LED
LED State
Description
Comments
Off
No link
No link, no communication present
Green
Link
Ethernet link established, no
communication present
Green,
Activity
Ethernet link established,
flickering
communication present
Ethernet Interface
The Ethernet interface operates at 100 Mbit, full duplex,
with autonegotiation enabled as default.
1
8
Comments
No power - or - Module in 'SETUP'
or 'NW_INIT' state
Module has shifted from the
'NW_INIT' state
Diagnostic event(s) present
Used by engineering tools to
identify the node on the network
Module in state 'EXCEPTION'
Expected Identification differs
from Real Identification
IP address not set
Station Name not set
Module has encountered a major
internal error