tion power will be reduced as will the
effectiveness of the filter if it is not re-
placed in good time.
How to replace the Active AirClean
30/HEPA AirClean 30 filter (dia. 28)
Do not use more than one exhaust fil-
ter at a time.
 Open the dust compartment lid.
 Lift the exhaust filter and remove it.
 Insert a new exhaust filter, making it
sure it goes in properly, then push it
down into position.
 Press the exhaust filter change indic-
ator (dia. 10).
After approx. 10 - 15 seconds, a thin
red line will appear in the left hand side
of the display (dia. 11).
If you wish to fit an AirClean filter,
see "Replacing one type of exhaust
filter with another".
 Close the dust compartment lid.
Replacing one type of exhaust filter
with another (dia. 07)
Depending on model, your vacuum
cleaner will be fitted as standard with
one of the following exhaust filters:
a AirClean
b Active AirClean 30 (black)
c HEPA AirClean 30 (white)
Do not use more than one exhaust fil-
ter at a time.
42

When changing the filter, please note

1. If you wish to replace exhaust filter a
with filter b or c, it is essential that
you remove the filter grille before you
fit the new exhaust filter.
You must also activate the exhaust
filter TimeStrip change indicator (dia.
10).
2. If you wish to replace exhaust filter b
or c with filter a, you must insert the
new filter into a filter grille * before in-
stalling (dia. 27).
* Filter grille - see "Optional ac-
cessories"

When to change the thread lifters

The thread lifters on the suction inlet to
the floorhead can be replaced. Check
them from time to time and replace
them if the pile has worn down.

How to replace the thread lifters

(dia. 29)
 Use a suitable screwdriver to remove
the thread lifters from the slots.
 Fit new thread lifters.
Replacement parts are available from
your Miele dealer or from the Miele
Spare Parts Dept.

Cleaning and care

Always disconnect the vacuum
cleaner from the electrical supply be-
fore cleaning it. Switch off at the wall
socket and unplug it.