Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Remote Control - Dometic TEC29 EV Montageanleitung

Vorschau ausblenden Andere Handbücher für TEC29 EV:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
Connecting the electrical power to the generator
➤ Connect the black wire to terminal 6 of the 6-pin plug on the extension cable.
➤ Connect the black wire to switch 1 (not included in the scope of delivery).
➤ Lead the black wire from switch 1 to the ground through a connection managed
by the ignition key.
10.7
Creating a priority circuit
You can create a priority circuit using the AG 102 changeover relay whereby the
external voltage supply has priority over the generator, see circuit diagram (fig. i,
page 12):
Item
Description
1
230 V external voltage supply
2
Vehicle electrical distribution system
3
Connection box
➤ Mount the AG 102 changeover relay in a suitable position.
➤ Disconnect the cable which links the mains input with the circuit breaker in the
electrical distribution system of the vehicle so that the connections can be made
as shown in the circuit diagram.
➤ Use a flat plug for connecting the cable to the switch.
➤ Connect A with plug-in sleeve 4 and B with plug-in sleeve 6.
➤ Connect the cable from the 230 V connection terminal of the generator to plug-
in sleeve 1 and plug-in sleeve 3.
10.8

Connecting the remote control

➤ Connect the remote control to the connection box of the generator using the
extension cable provided on the plug for the remote control (for TEC29 EV:
fig. e 3, page 10, for TEC29 EVLPG: fig. f 4, page 10).
10.9
TEC29 EV only: connecting the float
➤ Connect the float from the tank to the float connection (fig. e 4, page 10).
30
TEC29 EV, TEC29 EV LPG
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tec29 ev lpg

Inhaltsverzeichnis