Problem
The fan doesn't rotate
The fan rotates
without ventilating the
inside of the vehicle
* e
nsure that the power supply has been disconnected before carrying out

TROUBLESHOOTING

Cause
Power voltage is less
than 10 Vdc
The cables are
incorrectly connected
Foreign bodies are
blocking the blade
Power failure
Thermostat has
intervened
The room temperature
is under -10°C
None of the above
causes
Deviator in exhaust
position
any kind of operation
EN
Maintenance instructions
ES
Recomendaciones
Charge the battery,check
that the voltage is 12 Vdc
Check that connections
correspond to wiring
diagram*
Remove any obstructions
from the blade*
Check the fuses in the
main control panel*
Lower the intervention
point of thermostat
Raise the room tempera-
ture at a degree over the
-10°C
Contact your Fiamma
Service Centre
Set the deviator to
ventilation mode
,
than reconnect
COMFORT
Solution
.