Installation
GB
! Before placing your new appliance into operation please read these operating
instructions carefully. It contains important information concerning the safe
installation and operation of the appliance.
! Please keep these operating instructions for future reference. Make sure that
the instructions are kept with the appliance if it is sold, given away or moved.
! The following instructions should be carried out by a qualified technician
to ensure that the appliance is installed, adjusted and technically serviced
correctly in compliance with current regulations.
! Important: any adjustments, maintenance, etc. must be carried out
after the appliance has been disconnected from the electricity supply.
Whenever it is necessary to maintain the electrical connections, proceed with
extreme caution.
Positioning and levelling
! The appliance may be installed alongside any cupboards whose height does
not exceed that of the hob surface.
! Make sure that the wall in contact with the back of the appliance is made from
a non-flammable, heat-resistant material (T 90°C).
To install the appliance correctly:
• Place it in the kitchen, the dining room or the studio flat (not in the
bathroom).
• If the top of the hob is higher than the cupboards, the appliance must be
installed at least 500 mm away from them.
HOOD
600
Min.
mm.
• Any hoods must be installed in accordance with the instructions listed in
the relevant operating manual.
Levelling
Electrical connection
THE EQUIPMENT MUST BE EARTHED CORRECTLY.
The appliance is designed for operation with an alternating current at the
power supply voltage and frequency indicated on the data plate (this is located
underneath the appliance; alternatively the information may be found at the
end of the instruction manual).
Make sure that the local power supply voltage value is the same as the
value indicated on the data plate. The appliance does not come with a power
supply cable, because the size of this cable should be determined according
to the type of electrical connection used (see connection diagram below).
16
• If the cooker is installed underneath a wall
cabinet, there must be a minimum distance
of 420 mm between this cabinet and the top
of the hob.
This distance should be increased to 700
mm if the wall cabinets are flammable (see
figure).
• Do not position blinds behind the cooker or
less than 200 mm away from its sides.
If it is necessary to level the appliance, screw
the adjustable feet into the places provided
on each corner of the base of the cooker (see
figure).
Use a H05RR-F-type rubber cable. Open the terminal board, following the
instructions for the adjacent figure:
To install the power supply cable, follow the instructions below:
• Loosen the cable clamp screw "V" and the
wire contact screws.
• Fix the wires under the screw heads in
2
accordance with the following diagram.
1
2
1
3
4
5
V
Electrical connection
Power supply
voltage
230V -1+N ~ 50Hz
400V 2+N ~ 50Hz
400V -3+N ~ 50Hz
230V -2 ~ 50Hz
230V -3 ~ 50Hz
400V -2+2N ~ 50Hz
*Application of the simultaneity coefficient in compliance with the relevant
standard.
Replacing the cable
Use a rubber cable of the type H05RR-F with a suitable cross section of 3 x 4
mm². The yellow-green earth wire must be 2-3 cm longer than the other wires.
Connecting the supply cable to the mains
Install a standardised plug corresponding to the load indicated on the data
plate. The appliance must be directly connected to the mains using an
omnipolar circuit-breaker with a minimum contact opening of 3 mm installed
between the appliance and the mains. The circuit-breaker must be suitable for
the charge indicated and must comply with current electrical regulations (the
Cross-
Fuse
section
32* A
3x4 mm²
32 A
4x4 mm²
25 A
5x2.5 mm²
32* A
3x4 mm²
25 A
4x4 mm²
25* A
5x2.5 mm²