Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Power Cable - EINHELL PRESSITO Originalbetriebsanleitung

Hybrid-kompressor
Vorschau ausblenden Andere Handbücher für PRESSITO:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Switch in the middle: OFF
Switch to the right: Low-pressure operation
6.2 Compressor compressed air operation
(Fig. 1a, 1b, 2, 7)
To inflate objects with compressed air, use
the compressed air hose (5).
Connect the adapter of the compressed air
hose to the object you wish to inflate.
Depending on what you are inflating, also use
the adapters (7, 8, 9) or other adapters availa-
ble from retail stores.
The pressure at the compressed air hose will
be displayed in the display (11).
The unit of the displayed pressure can be se-
lected with the button (15). The pressure can
be displayed in units of [bar], [PSI] or [kPa].
The button (14) allows the desired pressure
to be reduced.
The button (16) allows the desired pressure
to be increased.
Switch on the equipment by moving the se-
lector switch (12) to the compressed air ope-
ration position (see 6.1.).
The compressor will then pump until the pre-
set pressure on the display is reached, then it
will switch off.
Warning! Observe the information supplied
by the tire manufacturer and the vehicle ma-
nufacturer relating to the recommended tire
pressure.
Warning! This equipment is not calibrated!
For a calibrated measurement value, check
the actual tire pressure using a calibrated me-
ter after you have inflated the tires yourself,
e.g. at a petrol station.
Just before it is switched off, the pressure
which is shown in the display can be 0.05 –
0.2 bar higher than the preselected pressure,
because of overpressure in the air hose.
Allow the compressor to cool down for about
5 minutes after every 5 minutes of operation
in order to prevent overheating.
Anl_PRESSITO_SPK9.indb 24
Anl_PRESSITO_SPK9.indb 24
GB
6.3 Low-pressure blower operation
(Fig. 1a, 3, 4)
6.3.1 Suctioning air (Fig. 3, 7)
To suction out objects with a large volume
until they are empty (e.g. deflating an air
mattress, etc.), connect the air hose (3) to the
extractor connection (13).
Connect the air hose to the object you wish
to deflate.
Switch on the equipment by moving the se-
lector switch (15) to the low-pressure operati-
on position (see 6.1.).
Switch off the equipment once the object has
been sufficiently deflated.
6.3.2 Infl ating (Fig. 4, 7)
Warning! When using the equipment to infl ate
objects, check the information and safety instruc-
tions provided by the manufacturer.
To inflate objects with a large volume (e.g.
inflating an air mattress, etc.), connect the air
hose (3) to the inflating connection (4).
Connect the air hose to the object you wish
to inflate.
Switch on the equipment by moving the se-
lector switch (12) to the low-pressure operati-
on position (see 6.1.).
Switch off the equipment once the object has
been sufficiently inflated.

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
- 24 -