Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly And Starting; Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts - EINHELL TC-AC 270/50/8 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

6. Assembly and starting

Danger!
You must fully assemble the appliance before
using it for the fi rst time.
6.1 Fitting the wheels (3)
Fit the supplied wheels as shown in Fig. 5.
6.2 Fitting the supporting feet (4)
Fit the supplied supporting feet (4) as shown in
Fig. 6.
6.3 Replacing the oil sealing plug (14)
Remove the transportation cover from the oil fi ller
opening with a screwdriver and insert the sup-
plied oil sealing plug (14) into the oil fi ller opening
(Fig. 7).
6.4 Fitting the air fi lter (1)
Use a screwdriver to remove the transportation
cover from the air fi lter connection.
Screw in the supplied air fi lter (Fig. 8).
6.5 Power supply
Long supply cables, extensions, cable reels
etc. cause a drop in voltage and can impede
motor start-up.
In the case of low temperatures below +5°C,
motor start-up is jeopardized as a result of
stiffness.
6.6 On/Off switch (8)
To switch on the compressor, pull out the knob
(8).
To switch off the compressor, press the knob (8)
back in. (Figure 2)
6.7 Adjusting the pressure: (Fig. 1,2)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be taken from the quick-
lock coupling (5).
6.8 Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
Anl_TE_AC_270_50_8_SPK13.indb 16
Anl_TE_AC_270_50_8_SPK13.indb 16
GB

7. Replacing the power cable

Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Warning!
Wait until the compressor has completely
cooled down. Risk of burns!
Warning!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
Danger!
After use, always switch off the equipment
immediately and pull out the power plug.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
ance. Ensure that no water can get into the
interior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensation water (Fig. 1)
Notice! To ensure a long service life of the pres-
sure vessel (2), drain off the condensed water by
opening the drain valve (11) each time after using.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
- 16 -
23.05.2022 07:56:04
23.05.2022 07:56:04

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

40.073.60

Inhaltsverzeichnis