2.4 Foreseeable cases of misuse

Maico is not liable for damages caused
by usage other than its intended purpose.
The fan unit should not be used:
● in single air extraction systems according
to DIN 18017-3.
● close to flammable materials, liquids or
gases.
● to convey chemicals, aggressive gases
or vapours.
● in potentially explosive atmospheres.
● outdoors
● if there is no protection against accidental
contact with the impeller on the discharge
side in accordance with EN ISO 13857.
3. Environmental conditions and
operating limits
● Permissible maximum temperature of air
medium + 40 °C.
● The domestic air supply must be set up so
that virtually no air can flow into the living
areas from the kitchen, bathroom and WC.
● A room from which the air has to be ex-
tracted must be fitted with a non-closable,
free supply air cross section of at least
150 cm²,
e.g. with Maico door ventilation
grille MLK.
● Sufficient supply air intake must be en-
sured during operation with air-ventilated
fireplaces. The maximum permitted
pressure difference per living unit is 4 Pa.
● VZ, F, KVZ and KF units: Resistance to
interference according to EN 55014-2
depending on pulse shape and energy
component 1000 to 4000 V. If operating
with fluorescent tubes, extra interference
suppression measures are needed (L or
C components or RC modules, protection
diodes, varistors) because these values
may be exceeded.

4. Technical data

See rating plate.
2. Product information │ UK

5. Safety instructions

5.1 General

● Read these operating instruc-
tions carefully before moun-
ting and commissioning.
● Assembly and electrical con-
nection may only be under-
taken by trained specialists in
accordance with Chapter 1.
● With electrical and equipment
installation the relevant
regulations must be observed,
in Germany particularly DIN
VDE 0100 with the correspon-
ding parts.
● Only connect unit to perma-
nently wired electrical instal-
lations with NYM-O or NYM-J
(2 x 1.5 mm² or 3 x 1.5 mm²)
cables. Mains isolation device
required with contact
openings of at least 3 mm at
each pole.
● The fan unit may only be
operated using the voltage
and frequency shown on the
rating plate.
● Only operate the fan unit
when it is completely
installed.
11