Securing the device
Screw the two brackets (marked with an arrow in the direction
of travel) to the device using the 4 provided M6 x 70 screws
(with screw sealant).
Torque 1.8 Nm
If the roof is more than 50 mm thick, M6 screws
(length = roof thickness + 30 mm) with tensile strength of 8.8
must be used. The screws must be secured with low-strength
screw sealant (e.g. Loctite).
Figure 24
If the screws are used more than once (e.g. after removal)
they must be coated with low-strength screw sealant again
(e.g. Loctite) or the screws provided as spare parts used.
Use of roof thickness adapters
Push base ring (1) and, depending on the thickness of the
roof, the roof thickness adapters (2 or 2+3, included) for roof
thicknesses of 25 to 50 mm into the air distributor as far as
they will go. If the roof is thicker, use additional 10 mm roof
thickness adapters (see Accessories). Maximum roof thick-
ness 110 mm
3
2
1
Figure 25
24
1,8 Nm
25 – 30 mm = 1
31 – 40 mm = 1+2
41 – 50 mm = 1+2+3
Securing the air distributor
Connect the cable from the air distributor to the electronics
unit.
Figure 26
Screw air distributor (arrow in direction of travel) to brackets
with 6 screws M6 x 12 mm.
The covering tape that is available as an accessory can
be used to compensate for the gap between the air dis-
tributor and the roof.
Figure 27
If the screws are used more than once (e.g. after removal)
they must be coated with low-strength screw sealant again
(e.g. Loctite) or the screws provided as spare parts used.