Caution
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
Operation
Danger
Risk of explosion!
Do not spray flammable liquids.
Danger
Risk of injury! Never use the appliance
without the spray lance attached. Check
and ensure proper fitting of the spray lance
prior to each use. The screw connection of
the spray lance must be fingertight.
Caution
Never operate device with empty fuel tank
The fuel pump will otherwise be destroyed.
Replace the nozzle
Danger
Switch the appliance off prior to replacing
nozzle and activate hand spray gun until
device is pressureless.
Operating modes
0/OFF = Off
1 Operating with cold water
2 Operating with hot water
3 Eco setting (hot water max. 60 °C)
Turning on the Appliance
Set appliance switch to desired operat-
ing mode.
Indicator lamp for operational readiness
lights up.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Release the trigger gun.
When activating the hand spray gun the de-
vice switches back on.
Note: If no water comes out of the high
pressure nozzle, vent pump. Refer to "Help
with malfunctions - appliance is not building
up pressure".
Adjust cleaning temperature
Set device switch to desired tempera-
ture.
Close the hand spray gun.
Turn the casing of the nozzle till the de-
sired symbol matches the marking.
High pressure flat spray (25°)
for large dirt areas
High pressure circular spray
(0°) for specially stubborn dirt
Flat low pressure spray
(CHEM) for operating using de-
tergents or cleaning at low
pressure.
Select round or flat spray using touch-less
switching:
Close the hand spray gun.
Turn the spray-pipe that is inclined
about 45° downward to the left or the
right.
– 5
EN
Triple nozzle
21