TMT162
Endress+Hauser
Registered trademarks of Microsoft Corporation, Redmond, USA
®
®
• iTEMP
and ReadWin
2000
Registered trademarks of Endress+Hauser Wetzer GmbH + Co. KG, Nesselwang, Germany
3
Installation
3.1
Quick installation guide
If the sensor is fixed then the unit can be fitted directly to the sensor. For remote mounting to a wall
or stand pipe, two mounting kits are available (→ Fig. 4). The illuminated display can be mounted
in four different positions (→ Fig. 2):
Fig. 2:
Temperature field transmitter with sensor, 4 display positions, can be plugged-in in 90° steps
A:
Sensor
1:
Cover clamp
2:
Housing cover with O-ring
3:
Display with retainer and twist protection
4:
Electronics compartment
1.
Remove the cover clamp (1).
2.
Unscrew the housing cover together with the O-ring (2).
3.
Remove the display with retainer and twist protection (3) from the electronics compartment
(4). Adjust the display with retainer in 90°-stages to the desired position and rearrange it on
the particular slot in the electronics compartment.
4.
Screw on the housing cover together with the O-ring. Mount the cover clamp.
Installation
61