i
Technical Specification
Model and recommended use
Item no.
4201 70 61
4202 70 61
Guide rail and available sizes
Item no.
4201 70 61
4202 70 61
Technical Data
Output:
Standby mode:
Tractive force:
Supply voltage:
Motor:
Light:
Door operating speed:
Transmission frequency and range:
Drive:
Method of protection:
Noise pressure level (LpA):
Permitted garage door dimensions
Permitted door leaf surface:
Maximum infill weight for
up-and-over doors:
68
Voltage (V)
Door size (m
≤ 10
220 – 240
max. total lenght
3140 mm
3740 mm
100 W
< 1 W
700 N
230 V / 50 Hz
24 V (DC) direct current
Power LED with timeout
11 cm/second
433 MHz/open terrain 50 m
chain
Use only in dry rooms
≤ 70 dB(A)
2
10.5 m
(for easy to move up-and-over doors and sectional doors)
2
7 kg/m
)
Admissible ambient temperature (°C)
2
–20...+40
Height of travel
2310 mm
2910 mm
max. lifting height
2250 mm
2850 mm
EN