CFX28 – CFX100W
➤ Press the fuse insert back into the housing.
➤ Reconnect the power supply to the device.
7.14
Replacing the plug fuse (12/24 V)
➤ Unscrew the contact pin housing (fig. 9 3, page 5) from the plug (fig. 9 1,
page 5).
➤ Replace the defective fuse (fig. 9 2, page 5) with a new fuse that has the same
rating (3AG, 15 A).
➤ Re-assemble the plug in reverse order.
7.15
Replacing the light PCB
➤ Disconnect the power supply to the device.
➤ Pry out the transparent cover with a screwdriver (fig. 0 1, page 5).
➤ Unscrew the PCB mounting screws (fig. 0 2, page 5).
➤ Pull out the plug from the PCB (fig. 0 3, page 5).
➤ Replace the defective light PCB with a new one.
➤ Fit new PCB using reverse of removal instructions.
➤ Press the transparent cover back into the housing.
➤ Reconnect the power supply to the device.
EN
Operation
23