Setting up and Installation
• The installation site for the outdoor sensor should be chosen so that it is located in a place
that is protected from precipitation (e.g. under the eaves), otherwise the sensor will not be
able to measure the air temperature any longer.
Nor must the sensor be exposed to direct sunlight (faulty measurements due to sunlight
exposure).
• Keep a sufficient distance to metallic surfaces, cables, power outlets or electrical devices
since they reduce the radio range.
• By means of the hole for the wall mounting (6), the outdoor sensor can be hung for example
on a screw or hook.
• The outdoor sensor may also be used standing upright.
Take care that the outdoor sensor is placed so it does not stand in or under water
(e.g. during rainfall), since water may enter through the holes in the bottom. The
outdoor sensor must not overturn!
The outdoor sensor must not be operated in, or under water, since this will damage
it!

Transmission range

Under optimal conditions, the transmission range of the outdoor sensor's radio signals is up
to 100 m. This is also often called the "free-field coverage".
However, this ideal arrangement (e.g. weather station and outdoor sensor on a plain, even
meadow without trees, houses etc.) never exists in practice.
Normally, the weather station is installed in the house or the outdoor sensor for temperature
and air humidity is mounted on the exterior of the house next to a window.
Due to the different influences on the radio transmission, no specific range can be guaranteed.
However, trouble-free operation is usually possible in a detached house.
When the weather station does not receive any data from the outdoor sensor (despite new
batteries), reduce the distance between outdoor sensor and weather station; change the
installation site.
The range can sometimes be reduced considerably due to:
• Walls, reinforced concrete floors
• Coated/metallised insulated glass
• Vehicles
• Trees, bushes, earth, rocks
• Proximity to metal & conducting objects (e.g. radiators)
• Proximity to human bodies
• Broadband interference e.g. in residential areas (mobile phones, radio headphones, radio
loudspeakers, other weather stations etc.)
• Proximity to electrical motors, transformers, mains adapters, computers, cables, power
outlets or other electrical devices
Maintenance and Cleaning
The product is maintenance-free for you; you should never dismantle it (except for inserting/
replacing the batteries or rechargeable batteries as described in these operating instructions).
Use a clean, dry soft cloth to clean the outdoor sensor.
Do not apply excessive pressure on the display. This may lead to scratches or
display malfunctions.
Never use aggressive cleansing agents or other chemical solvents, since they can
damage the surface of the housing or even impair operation.
Do not point a garden hose or other irrigation system or a high-pressure cleaner at
the outdoor sensor.
Declaration of Conformity (DOC)
We, Conrad Electronic, Klaus-Conrad-Straße 1, D-92240 Hirschau, hereby declare that this
product conforms to the fundamental requirements and the other relevant regulations in the
Directive 1999/5/EC.
You can find the declaration of conformity for this product at www.conrad.com.
Disposal
a) In general
Dispose of the product in accordance with the legal regulations that apply.
b) Batteries and rechargeable batteries
As the end user, you are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries; disposal of them in the household waste is prohibited!
Contaminated batteries/rechargeable batteries are labelled with these symbols to
indicate that disposal in domestic waste is forbidden.
The symbols for the relevant heavy metals are: Cd=cadmium, Hg=mercury,
Pb=lead (name on battery/rechargeable battery, e.g. under the trash icons on the
left).
You can dispose of your used batteries/rechargeable batteries free of charge at
your community's collection point or any place where batteries/rechargeable
batteries are sold!
You thereby fulfil your statutory obligations and contribute to the protection of the environment.
Technical Data
Temperature:
Measurement range ........................... -20°C to +60.0°C
Accuracy .............................................. +/- 1°C
Resolution ........................................... 0.1°C
Air humidity
Measurement range ........................... 25% to 90% relative humidity
Accuracy .............................................. +/-5% (in the range of 25% to 80%)
Resolution ........................................... 1%
General Information
Power supply ...................................... 2 batteries of type AA/Mignon
Battery life ........................................... Approx. 12 months
Transmission frequency ..................... 433MHz
Transmission range ............................ Up to 100m (open field, see chapter "Range")
Measurement cycle: ........................... Approx. every 43-47 seconds
Dimensions ......................................... Approx. 110 x 60 x 32mm (H x W x D)
These operating instructions are a publication by Conrad Electronic SE, Klaus-
Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment
reserved.
© Copyright 2010 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis