 Insert the suction hose into the suction
hose connection.
 Check the fill level in the dirt container
prior to starting work and empty the
container if necessary.
 Insert desired accessories.
Automatic monitoring of suction
capacity
The machine is equipped with a suction
power monitor. The control lamp "Vacuum
pressure" lights up red if the air speed in the
suction hose falls below 20 m/s (see "As-
sistance in case of malfunctions").
Note: The control lamp can light up occa-
sionally during normal operation (e.g.,
while working with a floor nozzle), if the air
volume comes down (cross-sectional re-
duction) causing a low pressure.
Note: There is no defect in this case; only
an indication that, as specified above, the
air volume has reduced and the low pres-
sure has increased.
Anti-static system
Static charge is deflected by providing
earthing to the connection nozzles. This
way, the electrically conductive accesso-
ries approved by the manufacturer prevent
the formation of sparks and current surges.

Operation

Dry vacuum cleaning
The appliance is equipped with a paper
filter bag fitted with locking lid.
Order No. Safety filter sack: 6.904-
420.0 (5 pieces)
Note: You can use this appliance to take up
all types of dust up to dust class H. It is stat-
utorily necessary to use a dust collection
bag (see Filter systems for order number).
Note: As an industrial vacuum cleaner the
appliance is suitable for vacuuming up dry,
combustible dusts with MAK values.
Unused flat-fold filters may only be
stored and transported in the packaging
(carton).
Illustration
The lamella of the flat-fold filter should
not be touched during installation.
Warning
The flat-fold filter and the safety filter sack
must never be removed during the dust ex-
traction process.
Installing the safety filter bag
 Release and remove the suction head.
Illustration
 Insert the safety filter sack.
Illustration
 Pull the safety filter sack over the con-
tainer.
 Insert and lock the suction head.
Wet vacuum cleaning
Danger
No dusts hazardous to health should be
sucked in during wet vacuuming.
To suck wet dirt, always remove the
safety filter bag.
Inserting the rubber lips
Illustration
 Remove the brush strips.
 Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Close the suction connection
Illustration
 Properly insert the connection socket in
the suction connection.
 Push in the connection socket until it
locks into place.
 Turn the suction connection with the
connection socket to the right to close it
tightly.
Note: The accurate fit is ensured by means
of a "bayonet connection".
Removing the safety filter sack
 Release and remove the suction head.
Illustration
 Pull over the safety filter sack.
– 4