  • DEUTSCH, seite 3

9 Switching the Blower On/Off

8.2

Removing the Activation Key

► Stand the blower on a level surface.
► Remove the activation key.
► Keep the activation key out of the reach of children.
9 Switching the Blower On/Off
9.1

Switching On

► Hold the blower with one hand on the control handle -
wrap you thumb around the handle.
► Push the release slide (1) in the direction of the blower
tube with your thumb and hold it there.
► Depress the trigger lockout (2) with your hand and hold it
there.
You can let go of the release slide (1).
► Pull the trigger (3) with your index finger and hold it there.
The blower accelerates and air flows from the nozzle.
9.2

Switching Off

► Release the trigger and lockout lever at the same time.
No air flows from the nozzle.
► If air continues to flow from nozzle: Remove the activation
key and contact your STIHL servicing dealer.
Blower has a malfunction.
0458-719-9621-A
1
2
3

10 Testing the Blower and Battery

10.1 Checking the Controls

Release slide, trigger lockout and trigger
► Remove the activation key.
► Try to pull the trigger.
► If the trigger can be pulled: Do not use the blower and
contact your STIHL servicing dealer.
Release slide or trigger lockout is faulty.
► Push the release slide (1) in the direction of the blower
tube with your thumb and hold it there.
► Depress the trigger lockout and hold it in that position.
► Pull the trigger.
► Let go of the trigger, trigger lockout and release slide.
► If the trigger, trigger lockout or release slide is stiff or does
not spring back to the idle position: Do not use the blower
and contact your STIHL servicing dealer.
The trigger, trigger lockout or release slide has a
malfunction.
Switching On
► Insert the activation key.
► Push the release slide (1) in the direction of the blower
tube with your thumb and hold it there.
► Depress the trigger lockout and hold it in that position.
► Pull the trigger and hold it there.
Air flows from the nozzle.
► If 3 LEDs flash red: Remove the activation key and contact
your STIHL servicing dealer.
Malfunction in blower.
► Release the trigger.
No air flows from the nozzle.
► If air continues to flow from nozzle: Remove the activation
key and contact your STIHL servicing dealer.
Blower has a malfunction.