Downloading Welding Reports From A Usb Stick Into Datawork On A Pc - Hürner USB 1000 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Using a USB cable, connect the PC to the almost square type B
USB port of the USB 1000 Box.
If it is not plugged into the PC, connect the other end of the cable
to the PC.
If it is not open yet, start the DataWork database management soft-
ware.
From the DataWork menu bar, access the option Transfer à Weld-
ing System --> PC à USB Port (see the DataWork manual).
A new window opens and printing should start automatically. The
red LED at "Active / Error" lights up and remains lit continuouly.
If an error message is displayed, please check the connections at
both the welding system and the USB 1000 Box.
When the data transfer is fully completed, the PC screen shows an
"OK" button, and the screen of the welding system displays "Printing
finished".
Disconnect the USB 1000 from the welding system.
Depending on the welding system you use, it may display the "Delete
protocols?" confirmation message after the cable was disconnected.
If you want to delete the reporting protocols from the memory of the
system, confirm by pressing the START (HST 300) or the ENTER
(CNC ECO) key. If you do not want to delete the reports in memory,
react to the confirmation message by pressing the STOP (HST 300)
or ESC (CNC ECO) key (see the manual of the welding system).
4.5
Downloading Welding Reports from a USB Stick into DataWork on
a PC
After saving the welding reports to a USB stick as described in section 4.2,
perform the following steps. Please read also the more detailed informa-
tion provided in the manual for DataWork, version 2.50 and higher.
Insert the USB stick to which the reports were saved into the proper
port of the PC.
If it is not open yet, start the DataWork management software and
create a new database or open the one to which the welding reports
should be appended.
From the DataWork menu bar, access the option Transfer à Data
Storage Unit --> PC à USB Stick (Report File (*.tdp)) (see the
DataWork manual).
A new window opens and lists all welding reports that were saved
to the USB stick.
Select the reports you want to import into the currently open Data-
Work welding database. To select a report file, click on the checkbox
next to the file name; the checkbox then appears ticked. Another
click on the box will deselect the selected file; the tick disappears.
When all report files you wish to import are selected, click on the
"Transfer" button.
When downloading the report files is finished an information mes-
sage is shown to tell you so. Confirm this message by clicking its
"Ok" button.
Finally, you may wish to delete on the stick the report files that were
just imported from it (for more details, see the DataWork manual).
Using the DataWork user interface to delete the files on the stick
means that they will be irrevocably lost. Your only possibility to
restore them on the stick would be to save them once more to
Wichtig
the USB stick from the welding system, provided you did not
delete them from the welding system memory after transfer.
When you are done importing the selected files and, possibly, delet-
ing them on the stick, close the window that opened for report file
import by clicking on it "Finish" button.
8
EN
USB 1000 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str.
35325 Mücke, Germany
Version January 2008