Herunterladen Inhalt Inhalt Diese Seite drucken

Reference Pressure Sensor Model Cpt7000 - WIKA CPH7000 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10. Specifications
Dieses Gerät erfüllt Teil 15 der FCC-Vorschriften.
Der Betrieb unterliegt den beiden folgenden Bedingungen:
1. Dieses Gerät darf keine schädlichen Störungen verursachen.
2. Dieses Gerät muss alle empfangenen Störungen annehmen, einschließlich Störungen, die zu unbeabsichtigtem Betrieb
EN
führen können.
FCC and IC Notice:
This instrument complies with part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This instrument may not cause harmful interference.
2. This instrument must accept any interference received, including interference that may cause undesired operation.
Cet instrument satisfait à la section 15 de la réglementation FCC
L'exploitation est autorisée aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.

10.5 Reference pressure sensor model CPT7000

Reference pressure sensor model CPT7000
Pressure range
Gauge pressure
10) Expanded accuracy of 0.075 % FS
58
bar
-0.25 ... +0.25
-0.4 ... +0.4
-1 ... +1
-1 ... +1.5
-1 ... +9
-1 ... +10
-1 ... +39
-1 ... +40
10)
0 ... 0.25
0 ... 0.4
0 ... 2.5
0 ... 4
0 ... 25
0 ... 40
0 ... 250
0 ... 400
psi
-4 ... +4
-6 ... +6
-14.5 ... +14.5
-14.5 ... +23
-14.5 ... +130
-14.5 ... +145
-14.5 ... +560
-14.5 ... +580
0 ... 4
0 ... 6
0 ... 36
0 ... 60
0 ... 360
0 ... 580
0 ... 3,630
0 ... 5,800
WIKA operating instructions portable process calibrator, model CPH7000
-0.6 ... +0.6
-1 ... 0
-1 ... +2.5
-1 ... +3
-1 ... +15
-1 ... +24
10)
0 ... 0.6
0 ... 1
0 ... 6
0 ... 10
0 ... 60
0 ... 100
0 ... 600
0 ... 700
-8 ... +8
-14.5 ... 0
-14.5 ... +36
-14.5 ... +44
-14.5 ... +220
-14.5 ... +350
0 ... 8
0 ... 14.5
0 ... 90
0 ... 145
0 ... 870
0 ... 1,450
0 ... 8,700
0 ... 10,150
-1 ... +0.6
-1 ... +5
-1 ... +25
0 ... 1.6
0 ... 16
0 ... 160
0 ... 1,000
-14.5 ... +8
-14.5 ... +70
-14.5 ... +360
0 ... 23
0 ... 230
0 ... 2,320
0 ... 14,500