Mounting and Connection Instructions Locking Sensor slimline with Magnetic Contact
- Insert contact unit
If, due to construction reasons, there
is insufficient space between the fra-
me and the leaf, the contact unit can
be inserted in wood or plastic con-
structions (sunk).
Make a recess as per the illustration
A) or B) on the right.
As regards the depth, ensure that the
distance "a" is within the stipulated
limits (1 - 7 mm, do not make full use
of the maximum range of 10 mm, if
possible).
5.

Connection diagram

Connection in Z-wiring:
The cable is connected by two lines for input and output which lie opposite one another.
To function correctly, it is not of importance which pair of cores are used as input or output.
Cable cross-section
Input
From previous contact
or from central control unit
The end of line resistor R must be connected behind the last contact.
Contact
Output
To next contact or
end of line resistor
A
8
A)
Mark
8
B)
Mark
1. Contact
Detector
group
15
min. 14
Last contact
R