Information "service"

Display
LQIRUPDWLRQ
VRIWZDUH 9
VHUYLFH
K
RSKRXUV
K

Information "operating hours"

Display
LQIRUPDWLRQ
VRIWZDUH 9
VHUYLFH
K
K
RSKRXUV

Information "extern request"

Display
LQIRUPDWLRQ
VHUYLFH
K
RS KRXUV
K
H[WUHT
RQ
Action
Description
Display for the next service according to operating
hours:
- Count begin: 2000 hours
- next service: 0 hours
Execute service, see chapter "Service"
Action
Description
The operating hours (op.hours) since commission-
ing, e.g. 12 h are shown.
Action
Description
As "extern request" (ext.req.) an external room ther-
mostat can be connected. Because the internal room
temperature sensor is also still connected the signal
WKDW ¿UVW VZLWFKHV ZLOO EH WDNHQ IRU FRQWURO ,I WKH WDU-
JHW WHPSHUDWXUH LV VSHFL¿HG ZLWK WKH H[WHUQDO URRP
thermostat, the adjustable room temperature must
be set to the maximum value (40°C) in "automatic"
operating status.
With the aid of the display you can check wheth-
er the external room thermostat has been correct-
ly connected and is taking over control of the ap-
pliance. When adjusting the room temperature on
the room thermostat above or below the actual room
temperature, "on" or "off" must be shown in the dis-
play.
If an external component is not connected, the dis-
play always shows "on".