4.1.2 Rear installation

Rear installation often causes an unfavourable
installation arrangement, as ideal ventilation
cannot always be assured (e.g. the ventilation
grilles are covered by installed accessories
such as bike racks!) The maximum cooling
performance of the aggregate is actually not
available.
An unfavourable method of rear installation is
to install the refrigerator lateral to the ventilati-
on grilles (Fig. 5).
The air-heat recirculation is very restricted
which means that heat exchangers (conden-
ser, absorber) cannot be adequately cooled.
The optional method of an additional air vent
grille installed in the floor also exhibits an
insufficient air flow duct.
CAUTION!
Do not apply this installation method, as it
does not provide proper ventilation!
Please refer to the description in section
4.2 .
Fig. 5
11
Installation