Overwriting the master
Switch off the radio receiver's power supply and switch it back on again after
10 seconds, or briefly press the radio receiver's programming button.
▻ The radio receiver remains in programming mode for 3 minutes.
To ensure that the new master transmitter is programmed in
the desired radio receiver only, all other receivers which are
connected to the same power supply must be deactivated
from the programming mode. To do so, after switching the
power back on, execute a drive or stop command using the
transmitter for the given receivers.
Now press the programming button of the new master transmitter for 10
seconds.
▻ The receiver confirms.
► The new master transmitter is now programmed and the old master
transmitter deleted.
Intermediate positions I + II
The intermediate positions I + II are freely selectable posi-
tions for the shading solution between the two limit posi-
tions. Each travel button can be assigned one intermediate
position. Both limit positions must be set before an interme-
diate position is set.
When both or individual limit positions are deleted, both in-
termediate positions are deleted as well.
Setting the desired intermediate position
Travel the shading solution from the corresponding limit position to the de-
sired intermediate position.
Now press the STOP button and, within 3 seconds, also press the travel button
of the corresponding limit position and hold the two buttons down.
▻ The receiver confirms.
► The intermediate position is now saved.
33 - en