Probe code
from 255 to 251
from 250 to 237
from 236 to 223
from 222 to 209
from 208 to 195
from 194 to 181
from 180 to 167
from 166 to 153
from 152 to 139
from 138 to 125
from 124 to 111
from 110 to 97
from 96 to 83
from 82 to 69
from 68 to 55
from 54 to 41
from 40 to 27
from 26 to 0
Each table contains 6 linearisation straight lines which are given for tables 2, 3, 4 and 5 (consult us if
necessary for the other tables).
The values for the start of the slope and end of slope correspond to the measurement values available
on rapid interrogation of measurement.
Coefficients of table 02 probe EF1 first sensitivity:
N° straight line
1
2
3
4
5
6
Linearisation table number
Measurement blocked
Start
0 ct
33 cts
250 cts
820 cts
2640 cts
11776 cts
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
End
33 cts
250 cts
820 cts
2640 cts
11776 cts
143360 cts
72
Measurement Unit
Display ANT
V/m
"
"
"
"
"
"
"
A/m
"
"
"
"
"
"
"
"
Coeff. a
4.666 10e-2
9.953 10e-3
5.438 10e-3
3.022 10e-3
1.893 10e-3
1.294 10e-3
Coeff. b
0
1.211
2.340
4.322
7.300
14.36