Herunterladen Diese Seite drucken

Troubleshooting; Scrapping - Nilfisk-ALTO scrubtec 233 Betriebsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ENGLISH

TROUBLESHOOTING

Trouble
The motors do not turn on.
Dirty water vacuuming is insuffi cient or there is no
vacuuming.
The solution fl ow is insuffi cient.
The brushes do not turn.
The squeegee leaves marks on the fl oor.
(*)
This maintenance procedure must be performed by Nilfi sk Alto authorised Service Center.
For further information refer to the Service Manual, available at any Nilfi sk Alto Service Center.

SCRAPPING

Have the machine scrapped by a qualifi ed scrapper.
Before scrapping the machine, remove and separate the following materials, which must be disposed of properly according to the
Law in force:
Brush
Pad
Electrical and electronic components (*)
(*)
Refer to the nearest Nilfi sk Alto Center especially when scrapping electrical and electronic components.
16
USER MANUAL
The power supply cable (10) is faulty or
disconnected from the electrical mains.
The recovery water tank (16) is full.
The vacuum grid (15) is clogged.
The vacuum hose (21) is disconnected from
the deck (9) or it is damaged.
The squeegees (12 - 13) are dirty or the
squeegee blades are worn or damaged.
The gasket of the transparent cover (15) is
damaged.
The vacuum system motor is faulty.
The solution fi lter (25) is dirty.
The driving belt is loose or torn.
The brush motor is faulty.
There is debris under the squeegee blades
(12 - 13).
The squeegee blades (12 - 13) are worn,
chipped or torn.
SCRUBTEC 233
Possible Cause
Remedy
Replace the cable or connect it.
Empty.
Clean.
Connect or replace.
Clean or replace the squeegees.
Check and/or clean the seating surface or
replace the gasket.
Replace. (*)
Clean.
Adjust or replace. (*)
Replace. (*)
Remove the debris.
Replace the blades.
9097883000(1)2008-06 A

Quicklinks ausblenden:

Werbung

Fehlerbehebung

loading