835
1 Byte
836, 866
2 Bytes
837, 867
2 Bytes
838, 868
2 Bytes
839, 869
1 Byte
1 Bit
840, 870
1 Bit
1 Bit
841, 871
1 Bit
1 Bit
842, 872
1 Bit
1 Bit
843, 873
1 Bit
844, 874
1 Bit
845, 875
1 Bit
846, 876
1 Byte
2 Bytes
847, 877
2 Bytes
848, 878
1 Bit
849, 879
2 Bytes
850, 880
2 Bytes
851, 881
2 Bytes
852, 882
2 Bytes
1 Bit
853, 883
1 Bit
854, 884
1 Bit
855, 885
1 Bit
856, 886
1 Bit
857, 887
1 Bit
858, 888
1 Byte
859, 889
1 Byte
1 Bit
860, 890
1 Bit
http://www.zennio.com
I
C - - W -
DPT_SceneControl
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Value_Temp
O
C T R - -
DPT_Value_Temp
I
C - - W -
DPT_HVACMode
I
C - - W -
DPT_Ack
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Ack
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Ack
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Ack
I
C - - W -
DPT_Switch
I
C - - W -
DPT_Window_Door
I
C - - W -
DPT_Ack
O
C T R - -
DPT_HVACMode
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Value_Temp
I
C - - W -
DPT_Step
I
C - - W -
DPT_Value_Tempd
O
C T R - -
DPT_Value_Temp
O
C T R - -
DPT_Value_Temp
O
C T R - -
DPT_Value_Tempd
I
C - - W -
DPT_Reset
I
C - - W -
DPT_Reset
I
C - - W -
DPT_Heat_Cool
O
C T R - -
DPT_Heat_Cool
I
C - - W -
DPT_Switch
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_Scaling
O
C T R - -
DPT_Switch
O
C T R - -
DPT_Switch
0-63; 128-191
[Thermostat] Scene Input
-273,00 - 670760,00
[Tx] Temperature Source 1
-273,00 - 670760,00
[Tx] Temperature Source 2
-273,00 - 670760,00
[Tx] Effective Temperature
1=Comfort
2=Standby
[Tx] Special Mode
3=Economy
4=Building Protection
0/1
[Tx] Special Mode: Comfort
0/1
[Tx] Special Mode: Comfort
0/1
[Tx] Special Mode: Standby
0/1
[Tx] Special Mode: Standby
0/1
[Tx] Special Mode: Nacht/Öko
0/1
[Tx] Special Mode: Nacht/Öko
0/1
[Tx] Special Mode: Protection
0/1
[Tx] Special Mode: Protection
0/1
[Tx] Window Status (Input)
0/1
[Tx] Comfort Prolongation
1=Comfort
2=Standby
[Tx] Special Mode Status
3=Economy
4=Building Protection
-273,00 - 670760,00
[Tx] Setpoint
-273,00 - 670760,00
[Tx] Basic Setpoint
0/1
[Tx] Setpoint Step
-670760,00 - 670760,00 [Tx] Setpoint Offset
-273,00 - 670760,00
[Tx] Setpoint Status
-273,00 - 670760,00
[Tx] Basic Setpoint Status
-670760,00 - 670760,00 [Tx] Setpoint Offset Status
0/1
[Tx] Setpoint Reset
0/1
[Tx] Offset Reset
0/1
[Tx] Mode
0/1
[Tx] Mode Status
0/1
[Tx] On/Off
0/1
[Tx] On/Off Status
0% - 100%
[Tx] Control Variable (Cool)
0% - 100%
[Tx] Control Variable (Heat)
0/1
[Tx] Control Variable (Cool)
0/1
[Tx] Control Variable (Cool)
Scene Value
External Sensor Temperature
External Sensor Temperature
Effective Control Temperature
1-byte HVAC Mode
0 = Nothing; 1 = Trigger
0 = Off; 1 = On
0 = Nothing; 1 = Trigger
0 = Off; 1 = On
0 = Nothing; 1 = Trigger
0 = Off; 1 = On
0 = Nothing; 1 = Trigger
0 = Off; 1 = On
0=Closed; 1=Open
0 = Nothing; 1 = Timed
Comfort
1-byte HVAC Mode
Thermostat Setpoint Input
Reference Setpoint
0 = -0.5ºC; 1 = +0.5ºC
Float Offset Value
Current Setpoint
Current Basic Setpoint
Current Setpoint Offset
Reset Setpoint to Default
Reset offset
0 = Cool; 1 = Heat
0 = Cool; 1 = Heat
0 = Off; 1 = On
0 = Off; 1 = On
PI Control (Continuous)
PI Control (Continuous)
2-Point Control
PI Control (PWM)
Technischer Support:
http://support.zennio.com