OP1S Operator Control Panel
2.2 Run-up
After the power supply for the unit connected to the OP1S has been turned on or after
the OP1S has been plugged into a unit which is operating, there is a run-up phase.
CAUTION
The OP1S must not be plugged into the Sub-D socket if the
!
SCom1 interface parallel to the socket is already being used
elsewhere, e.g. bus operation with SIMATIC as the master.
In the as-delivered state or after a reset of the parameters to the factory
NOTE
setting with the unit's own control panel, a point-to-point link can be adopted
with the OP1S without any further preparatory measures.
When a bus system is started up with the OP1S, the slaves must first be
configured individually. The plugs of the bus cable must be removed for this
purpose (see section "Bus operation").
During the run-up phase, the text "Search slave" is shown in the first line of the display,
followed by "Slave found" and the found slave number as well as the set baud rate.
Slave found
Example of a display after the run-up
[00]
Address:
phase (6 corresponds to 9.6 kBd)
Baud rate: [6]
After approximately 4 s, the display changes to
SIEMENS
Example of what is displayed after a
MASTERDRIVES MC
slave address has been found
6SE7014-0TP50
SW:V1.0 OP:V2T20