Herunterladen Inhalt Inhalt Diese Seite drucken

Lcd Status Messages Update - Dell PowerEdge 2900 serie Handbuch

Aktuelle informationen
Vorschau ausblenden Andere Handbücher für PowerEdge 2900 serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 80
Table 1-1. System Messages (continued)
Message
Warning: The
installed memory
configuration is
not optimal. For
more information
on valid memory
configurations,
please see
the system
documentation
on the technical
support web site.
Write fault
Write fault on
selected drive

LCD Status Messages Update

Table 1-2 lists updates to the LCD status messages that can occur on
the PowerEdge 2900 III system and the probable cause for each message.
The LCD messages refer to events recorded in the system event log (SEL).
For information on the SEL and configuring system management settings,
see your systems management software documentation.
14
Information Update
Causes
Invalid memory
configuration. The system
runs but with reduced
functionality.
Faulty USB device, USB
medium, optical drive
assembly, hard drive, or
hard-drive subsystem.
Corrective Actions
Ensure that the memory
modules are installed in
a valid configuration. See
"General Memory Module
Installation Guidelines"
in the Hardware Owner's
Manual. If the problem
persists, see
"Troubleshooting System
Memory" in the Hardware
Owner's Manual.
Replace the faulty media.
Reseat the USB device or
USB cable. For hard drive
problems, see
"Troubleshooting a Hard
Drive" in the Hardware
Owner's Manual.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis