Redirecting The Drac/Mc Serial Console To The Ethernet Switch Module; Updating The Drac/Mc Module Firmware - Dell PowerEdge 1955 Serie Konfigurationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

10 Type racreset and press <Enter> to reset the controller.

Redirecting the DRAC/MC Serial Console to the Ethernet Switch Module

Redirect the DRAC/MC serial console to the Ethernet switch module internal serial console
interface by entering the following command:
connect switch-n
where n is the system enclosure I/O module bay number in which the Ethernet switch module is
installed.
NOTE:
To switch back to the context of the DRAC/MC CLI command prompt, press <Enter><~><.>.
After the switch module is connected to the console, wait until the Ethernet switch module is fully
booted. Observe the booting information being displayed on the terminal window and wait for the
switch module prompt to appear. Press <Enter> several times to ensure that the terminal
connection is successfully established and the switch module can be configured through the CLI.
NOTE:
The switch module's system indicator is off when the module is enabled and operating normally.
If the switch has been disabled by the DRAC/MC, or there are hardware or firmware issues, the indicator
will turn green.

Updating the DRAC/MC Module Firmware

NOTICE:
Updating your DRAC/MC firmware will disconnect your current network connection.
Use one of the following methods to update your DRAC/MC firmware:
Web-based Interface — See "Using the DRAC/MC Web-based Firmware Update Interface"
on page 20.
RACADM CLI — See "Using the RACADM CLI to Update the DRAC/MC Firmware"
on page 21.
Firmware Recovery Console — See "Using the Firmware Recovery Console" on page 22.
General System Configuration
19