manufacturer will be liable for any damage or inju-
ries of any kind caused as a result of this.
Please note that our equipment has not been de-
signed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.
4. Technical data
Power supply: ......................................... 18 V DC
AC Output: ........ 220-240V ~ 50Hz – max. 150W
USB-A Output: ............... 5V DC – max. 2A / 10W
USB-C PD Output: ...................... 5V DC, 9V DC,
12V DC, 15V DC, 20V DC – max. 3A / 60W
LED light max.: ............................................ 2.2W
Important!
The equipment is supplied without batteries and
without a charger and is allowed to be used only
with the lithium-ion batteries of the Power X-
Change series!
The lithium-ion batteries of the Power X-Change
series are allowed to be charged only with the
Power X charger.
5. Before use
5.1 Fitting the battery (Fig. 3)
Push the battery fully into the battery mount until
it latches into place. To remove the battery, press
the pushlock button (C) and pull the battery out of
the battery mount.
5.2 Charging the Li battery (Fig. 3-4)
1. Take the battery pack out of the equipment.
Do this by pressing the pushlock button.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
into the socket outlet. The green LED will then
begin to blink.
3. Insert the battery pack into the charger.
In section 10. „Charger indicator" you will fi nd a
table with an explanation of the LED indicator on
the charger.
Anl_TC-ES_18-150-1_Li_SPK13.indb 13
Anl_TC-ES_18-150-1_Li_SPK13.indb 13
GB
If the battery pack fails to charge, check:
•
whether there is voltage at the socket outlet
•
whether there is good contact at the charging
contacts
If the battery pack still fails to charge, send
•
the charging unit
•
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and fi res.
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
5.3 Battery capacity indicator (Fig. 5)
Press the button for the battery capacity indicator
(A). The battery capacity indicator (B) shows the
charge status of the battery using 3 LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
- 13 -
03.03.2025 14:31:06
03.03.2025 14:31:06