4.5 Electrical mounting
Destruction of parts of equipment and loss of regulation control
WARNING
` All lines for connecting the magnetic sensor must be shielded.
` Do not disconnect or close live connections.
` Perform wiring work in the de-energized state only.
` Before switching on operating voltage check all wiring and plug con-
` Switch on operating voltage together with downstream electronics (e.
Loss of explosion protection according to ATEX in case of the following
WARNING
installation faults
` Operation without safety barrier.
` Wrong, unsuitable safety barrier connected.
` Cable shield also connected to the barrier portion.
` Overriding of the safety barrier.
Basically, all connections are protected against external interference.
NOTICE
Choose an operating site that prevents inductive or capacitive interfer-
ence from influencing the magnetic sensor or its connection lines. Mount
the system at maximum distance from connections that are charged with
interference. If necessary, provide additional installations including
screening shields or metallized housing
` Pay attention to the maximum length of the connection cable between
NOTICE
` Do not use tinned strands in connection with screw clamp connec-
MSK210SKF ATEX · Date 30.03.2016 · Art. No. 86868 · Mod. status 86/16
Active side magnetic strip
Admissible deviation of strip/sensor 0.1 ... 1 mm
Admissable deviation middle of tape/sensor ±2 mm
Maximum alignment error
Area on shaft for threaded pin is recommended
nections.
g. control unit).
sensor and downstream electronics.
tions.