2.9 Malfunction and remedy
Attention
All work on the refrigeration system is to be
done by specialised persons only
Malfunction
The appliance is plugged in but
compressor and evaporator fail
to function
Appliance runs but no conden-
sation forms on evaporator
Possible Cause
a) No current
b) Hygrostat incorrectly set
c) Technical fault in refrigeration
system
a) Operating temperature range
not reached or exceeded
b) Operating air humidity range
not reached
c) Suction wall or blow-out wall
obstructed
d) Technical fault in refrigeration
system
Remedy
a) Check fuses and electrical
connections
b) Check hygrostat setting
c) Contact after-sales service
a) Use appliance in correct
temperature range conditions or
adjust room temperature accor-
dingly
b) Use appliance only at 30 %
humidity or above
c) Allow adequate clearance of
the appliance, clean or change
the airfilter.
d) Contact after-sales service