3. Specifications

3. Specifications

3.1 Dry-well temperature calibrator, CTD9100 series

GB
Temperature range
Accuracy
Stability
Display resolution
Gradients, axially
1)
Heating time incl. stabilisation
Cooling time incl. stabilisation
Immersion depth
Insert dimensions
Voltage supply
Power supply
Power consumption
Power cord
Communication
Interface
Case
Dimensions
Weight
Temperature range
Accuracy
Stability
Display resolution
1)
Gradients, axially
Heating time incl. stabilisation
Cooling time incl. stabilisation
Immersion depth
Insert dimensions
Voltage supply
Power supply
Power consumption
Power cord
Communication
Interface
Case
Dimensions
Weight
1) The gradient is understood to be the temperature change in the test well over the first 40 mm from the bottom of the sleeve.
2) The reference thermometer with which the measurements are performed, has a diameter of 6 mm.
3) Instrument design available with multi-voltage power supply
8
CTD9100-COOL
-55 ... +200 °C
0.15 ... 0.3 K
±0.05 K
0.01 to 100 °C, then 0.1
< 0.04 K at 200 °C
2)
15 min from 20 to 200 °C
2)
10 min from +20 to -20 °C
150 mm
Ø 28 x 150 mm
AC 100 ... 240 V, 50/60 Hz
555 VA
for Europe, AC 230 V
RS-485
215 x 305 x 425 mm (W x H x D)
11 kg
CTD9100-450
40 ... 450 °C
0.3 ... 0.5 K
±0.05 K at 100 °C
±0.1 K at 450 °C
0.01 to 100 °C, then 0.1
0.05 K at 100 °C
0.2 K at 450 °C
2)
14 min from 20 to 450 °C
2)
58 min from 450 to 100 °C
150 mm
Ø 60 x 150 mm
AC 230 V, 50/60 Hz
2,000 VA
for Europe, AC 230 V
RS-485
150 x 270 x 400 mm (W x H x D)
7.5 kg
WIKA operating instructions, models CTD9100, CTB9100, CTM9100
CTD9100-165
-35 ... +165 °C
0.15 ... 0.25 K
±0.05 K
0.01 to 100 °C, then 0.1
< 0.04 K up to 100 °C
0.06 K up to 165 °C
12 min from 20 to 165 °C
7 min from +20 to -20 °C
150 mm
Ø 28 x 150 mm or Ø 60 x 150 mm
AC 100 ... 240 V, 50/60 Hz
375 VA
for Europe, AC 230 V
RS-485
215 x 305 x 425 mm (W x H x D)
11 kg
CTD9100-650
40 ... 650 °C
0.3 ... 0.8 K
±0.05 K at 100 °C
±0.1 K at 600 °C
0.01 to 100 °C, then 0.1
< 0.2 K at 100 °C
0.5 K at 600 °C
28 min from 20 to 600 °C
60 min from 600 to 100 °C
150 mm
Ø 28 x 150 mm
3)
AC 230 V, 50/60 Hz
1,000 VA
for Europe, AC 230 V
RS-485
150 x 270 x 400 mm (W x H x D)
8 kg