the tool from the compressed air supply and it is recommended to empty the
magazine.
The compressed air connectors of the fastener driving tool and the hoses should
be protected against contamination, the ingress of coarse dust chips, sand etc, will
result in leaks and damage to the fastener driving tool and the couplings.
5. Maintenance
Disconnect the tool from the compressor before adjusting, clearing jams, servicing
&maintenance, relocating and during non operation.
Regular lubrication, if your tool without using the in-liner automatic oilier, place 2 or
6 drops of pneumatic tool oil into the air inlet before each work day or after 2 hours
of continuous use depending in the characteristic of work piece or type of
fasteners.
Air-operated tools must be inspected periodically, and worn or broken parts must
be replaced to keep the tool operating safely and efficiently. Check and change all
worn or damaged O-ring, Seals, etc. Tighten all the screws and caps to avoid
personal injury. This should be done by an expert.
Make regular inspection for free movement of trigger, spring and safety
mechanism to assure safe system is complete and functional: no loose and
missing parts, no building or stocking parts.
Keep magazine and nose of tool clean and free of any dirt lint or abrasive particles.
When temperatures are below freezing, tools should be kept warm by any
convenient, safe method.
- 11 -