3
6.
Adjusting of CO
- pressure
2
Turn the screw of the pressure regulator clockwise until the red LED indicator on the right side of the operator panel
turns off. Increase the pressure further while at the same time dispensing sodawater in short shots.
Increase the pressure until you notice an unstable water flow at the dispense nozzle and CO
Afterwards turn the CO
The CO
-pressure is in this setting just below the incoming water pressure (approx. 0,2 bar lower)
2
In case of fluctuating water pressures the gas pressure must be set to the lowest occuring water pressure in order to
ensure a stable flow of water in all events.
7.
Adjustment of water temperature
The water temperature can be set between approx.6 °C und 12 °. The adjustment is done via the knob under the unit cover.
Warmer
turn counterclockwise
Colder
turn clockwise
If the temperature knob set to „0" the cooling circuit is completly turned off.
In case of new installations it is recommended to start with the coldest setting (= 7) and
if required to turn the temp. up. Adjust the temperature to your customers wishes.
The colder the setting is, the better CO
Once the unit has been in operation it must be protected against frost. Remaining freezing water in the inline
carbonation module will cause damages of the module !
– pressure slightly back until the flow stabilized and no gas is exiting the nozzle.
2
1 = ~ 12°C
2 = ~ 11°C
3 = ~ 10°C
4 = ~ 9°C
– levels are achieveable !
2
3
2
5 = ~ 8°C
6 = ~ 7°C
7 = ~ 6°C
–gas exiting
Temperature knob
Page 41