Herunterladen Diese Seite drucken

Données Techniques; Operating Elements - Conrad DS-500 Bedienungsanleitung

Werbung

the mains outlet.
Only fuses of the type stated and rated current specified may be used. The use of repaired or
defective fuses is not permitted under any circumstances.
Never operate the apparatus immediately after bringing it from a cold room into a warm room.
Condensed water may destroy the apparatus under adverse circumstances. Leave the apparatus
turned off until it has reached room temperature. This might take several hours.
The power plug must always be inserted without force. Make sure that the plug is tightly connected
to the mains outlet.
Never pull the power cord to withdraw the plug from outlet. Always use the grip areas provided. The
same applies for the power jack on the apparatus.
This apparatus is not a toy and should be kept out of reach of children or pets! When operating the
apparatus in the presence of children, be exceptionally cautious.
Packaging material, such as plastic foil or bags, Styrofoam parts etc., could become dangerous toy
for children. Never leave it lying around carelessly.
Safe operation is no longer possible if:
-
the apparatus shows visible damages,
-
the apparatus no longer works,
-
the apparatus was stored under unfavourable conditions for a long period of time and
-
the apparatus was subject to considerable transport stress.
Qualified personnel should monitor the operation of this product in schools and training facilities
and hobby and DIY workshops in a responsible manner.
In commercial institutions, the safety regulations applicable to electrical equipment and relevant
operating resources of the employers' liability insurance association must be observed.
Servicing, adjustment or repair works must only be carried out by a specialist/ specialist
workshop.
If any questions arise that are not answered in this operating instruction, contact our Technical
Advisory Service or other experts.

Operating elements

1.
Cinch input
2.
Power indicator
3.
Operating mode selector
4.
Low Frequency Effects (LFE) selector
5.
Volume knob
6.
Phase regulator
7.
Crossover frequency knob
8.
Mounting holes
9.
Heat sink
10.
Fuse cabinet
11.
Mains connection jack
12.
Power switch
13.
Output wires
12
Données techniques
Tension de fonctionnement
Puissance consommée
Auto-marche tension de seuil
Sensibilité d'entrée
Impédance d'entrée
Puissance de sortie (4 /8Ω)
Réponse en fréquence
Répartiteur de basse à niveau bas
Coefficient K
Rapport signal sur bruit
Distortion
Amplification de basses fréquences
Délai automatique de mise hors tension
Fusible (5 x 20 mm)
Dimension (longueur x largeur x hauteur)
Température de fonctionnement
230V~/
50Hz
ou
115V~/60Hz
(aiguillage
automatique)
600W (maximum)
12W (en attente)
5.2mV
150 mV à 100Hz signal sinus
20 kΩ
500W/ 340W
25Hz - 160Hz
50Hz - 160Hz
30
77dB
0.5% ou 500W
4.8dB (caisson de basse)
3dB (LFE)
approx. 16min
F4AL250V
285 x 215 x 104 mm
0°C – 50°C
21

Werbung

loading