Troubleshooting

9
Troubleshooting
Fault
Device does not func-
tion, LED does
not glow.
The device does not
cool (plug is inserted,
"POWER" LED is lit).
The device does not
cool (plug is inserted,
"POWER" LED flashes
orange, display is
switched off).
The display shows an
error message (e.g.
"Err1") and the appli-
ance does not cool.
10

Disposal

➤ Place the packaging material in the appropriate recycling waste
bins wherever possible.
If you wish to finally dispose of the product, ask your local recycling
M
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
38
Possible cause
Battery voltage is too
low.
No voltage present in the
AC voltage socket.
The device fuse is defec-
tive.
The integrated mains
adapter is defective.
Defective compressor.
Battery voltage is too
low.
The appliance has
switched off due to an
internal fault.
Suggested remedy
Test the battery and charge it as needed.
Try using another plug socket.
Replace the device fuse, see "Replacing
the device fuse" on page 36.
This can only be repaired by an author-
ised repair centre.
This can only be repaired by an author-
ised customer services unit.
Test the battery and charge it as needed.
This can only be repaired by an author-
ised repair centre.