Cleaning
The product is to be cleaned with hot water or a mild soapy cleaning agent.
To see which cleaning products have been tested and approved by Pressalit
for the specific product, please visit Pressalit.com and refer to the product's
item number. Pressalit recommends cleaning the product after installation.
Always read the material safety data sheet (MSDS) and supplied
instructions of the cleaning, disinfecting or de-scaling agent and comply
with instructions for safe use, dilution, rinsing, drying, handling and
storage of the agent.
• Do not use an autoclave or other type of steam cleaner.
• Avoid aggressive cleaning agents containing acids.
• Never spray the product directly with a high pressure cleaner.
• Avoid use of abrasive, corrosive or chlorine-based cleaning or
disinfecting products.
Trouble-shooting
Symptom
The call button does
not work.
The support arms
drop down to fast.
The support arms are
loose/unstable.
CAUTION
!
IMPORTANT
Cause
The plug for the button
has been pulled out.
The adjustment screws
are too loose.
The mounting screws
have become loose.
Action
Put the plug back into
the socket.
Tighten the three
adjustment screws.
See "Adjustment".
Tighten the mounting
screws.
See "Maintenance".
en
11