13.5
Switching on the machine by an electrical amateur
Switching on without a qualified electrician, the following requirements must be met:
The machine is checked at regular intervals by a qualified electrician (recommended every six
•
months).
•
Extension and connection cables as a well as plugs/sockets must be checked regularly for me-
chanical damage.
•
Only use cables and conductors that are permanently suitable for the intended use.
13.6
Operating Instructions
Always place the machine on a firm and flat surface! No turning, tilting or moving dur-
•
ing the engine is running.
•
Always check oil and fuel level before starting.
•
Do not connect the device before the machine is running at full speed. Disconnect the
device before turning the machine off.
•
Connected devices must be in perfect condition.
•
Keep the cable length to the device as short as possible.
13.6.1
Operation of the machine over 1800m above sea level
When operating at high altitudes, the air/fuel mixture becomes too dense due to the lower ox-
•
ygen content in the air. This leads to loss of power, increased fuel consumption, rapid wear of
the spark plugs and difficult starting of the engine.
13.6.2
Connecting devices to AC-sockets
Before connecting a device to the machine you must check its perfect condition.
•
When you recognize that a connected device acts unusual you must stop the machine and dis-
•
connect the device. Control whether the device is damaged or if the machine was overloaded
by the device.
The max. performance of the connected devices must be within the specifications for the ma-
•
chine.
NOTE:
Most devices (motor) require more starting current to start than specified. A short exceed of the
normed power capacity of the machine is possible but if this happens oftener the life time of the ma-
chine will be shortened.
Please consult the performance specifications on the connected electrical devices, these can usually
be found next to the serial or manufacturing number.
Please consider: Some devices, for instance cooling devices need up to 5 times more starting current
than current during the operation.
13.7
Operation
13.7.1
Switch the engine/machine on
NOTE:
If devices are connected to the machine, disconnect them.
13.7.2
Switch the machine off
In case of emergency stop the machine directly with the ON-OFF switch.
Under normal circumstances, switch off the machine as follows:
•
Shut down the connected devices and disconnect them from the machine.