9. Registering the DuoFern sun sensor

i
You must register the DuoFern sun sensor with every required actuator so that the DuoFern
sun sensor can control the DuoFern actuator you wish. You can register the DuoFern sun sensor
with a maximum of five DuoFern actuators.
NOTE
All settings can only be made when the sun sensor is charged up. If the internal energy store
has run out of charge, the status LED (1) flashes red twice. If this happens, you need to recharge
the sun sensor (see page 22).
1.
Switch the DuoFern actuator to login mode
(please refer to the relevant operating instructions).
2.
3.
The DuoFern sun sensor now transmits a login signal. Login mode remains active for 10 seconds.
If registration is successful, the status LED (1) lights up green for two seconds.
4.
Register the next DuoFern actuator by repeating 1 to 2, or exit login mode.
5.
NOTE
The status LED (1) lights up red for two seconds if the login process fails, for example if:
◆ the maximum number of registrations (max. 5 actuators) for the DuoFern sun sensor
has already been reached.
◆ the maximum number of registrations has already been reached for the DuoFern actuator.
◆ an unsuitable device (e.g. other DuoFern sensor) is registered.
◆ the login period expired without an actuator being logged in.
Press the Connect button (2) quickly once.
EN
23