HYGRASGARD
®
KFTF 20 - wModbus
HYGRASGARD
®
D
Bedienungs- und Montageanleitung
Kanal- Feuchte- und Temperaturfühler (± 1,8 % ⁄ ± 2,0 %),
inkl. Montageflansch, für Mischungsverhältnis, relative ⁄
absolute Feuchte, Taupunkt, Enthalpie und Temperatur, kalibrierfähig,
mit W-Modbus (Wireless)
G U
Operating and Mounting Instructions
Duct humidity- and temperature sensors (± 1.8 % ⁄ ± 2.0 %),
incl. mounting flange, for mixture ratio, relative ⁄ absolute humidity,
dew point, enthalpy and temperature, calibratable
with W-Modbus (Wireless)
F
Notice d'instruction
Sonde de température et d'humidité pour montage en gaine
(± 1,8 % ⁄ ± 2,0 %), y compris bride de montage, pour rapport
de mélange, humidité relative ⁄ absolue, point de rosée, enthalpie
et température, étalonnable, avec W-Modbus (Wireless)
r
Руководство по монтажу и обслуживанию
Канальный датчик влажности и температуры (± 1,8 % ⁄ ± 2,0 %),
вкл. присоединительный фланец, для измерения соотношения
компонентов смеси, относительной ⁄ абсолютной влажности,
точки росы, энтальпии и температуры, калибруемый,
с W-Modbus (Wireless)
6000-4310-0000-1XX 43100-2024 V101 08 ⁄ 2024
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Werbung

loading

Inhaltszusammenfassung für S+S REGELTECHNIK HYGRASGARD KFTF

  • Seite 1 вкл. присоединительный фланец, для измерения соотношения компонентов смеси, относительной ⁄ абсолютной влажности, точки росы, энтальпии и температуры, калибруемый, с W-Modbus (Wireless) S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄ 5 19 47- 0 ET EMBALLAGE mail@SplusS.de...
  • Seite 2 D G U F r KFTF - wModbus HYGRASGARD ® KFTF 20 - wModbus HYGRASGARD ® KFTF - wModbus Maßzeichnung Dimensional drawing KFTF 20 - wModbus Plan coté Габаритный чертеж [mm] mit Display with display avec écran с дисплеем M20x1.5 ohne Display without display sin écran...
  • Seite 3 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Kalibrierfähiger Kanal-Feuchte- und Temperatursensor HYGRASGARD ® KFTF - wModbus (± 2,0 %) oder KFTF -20 - wModbus (± 1,8 %), mit W-Modbus (Wireless), im schlagfesten Kunststoff gehäuse mit Schnellverschlussschrauben, wahl weise mit ⁄ ohne Display, mit Kunststoff - Sinterfilter (austausch- bar), inkl.
  • Seite 4 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Schaltbild HYGRASGARD ® Stecker belegung ® HYGRASGARD xx - wModbus xx - wModbus (M12) offset MALE DIP A 1 2 3 4 5 6 7 8 address Stecker Display 1 2 3 4 pair free –UB GND...
  • Seite 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Anschluss Achtung! Berücksichtigen Sie in jedem Fall die mechanischen und der Geräte darf nur an Sicherheitskleinspannung er folgen. Folgeschäden, thermischen Belastungsgrenzen der Schutzrohre nach DIN 43763 welche durch Fehler an diesem Gerät entstehen, sind von der Gewähr- bzw.
  • Seite 6 Wichtige Hinweise Hiermit erklärt S+S Regeltechnik GmbH, dass der Funkanlagentyp KFTF (20) - wModbus der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EU-Konformitätserklärung ist unter folgenden Internetadresse verfügbar: www.spluss.de/120132CF1000029/ – Dieses Gerät darf nur in schadstofffreier, nicht kondensierender Luft eingesetzt werden.
  • Seite 7 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Calibratable duct humidity and temperature sensor HYGRASGARD ® KFTF - wModbus (± 2.0%) or KFTF 20 - wModbus (± 1.8%), with W-Modbus (Wireless), in an impact-resistant plastic housing with quick-locking screws, optionally with ⁄ without display, with a plastic sinter filter (exchangeable), incl.
  • Seite 8 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Schematic diagram HYGRASGARD ® Pin assignment ® HYGRASGARD xx - wModbus xx - wModbus (M12 option) offset MALE DIP A 1 2 3 4 5 6 7 8 address Plug for display 1 2 3 4 pair...
  • Seite 9 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices Attention! In any case, please observe the mechanical and thermal must only be connected to safety extra-low voltage. Consequential load limits of protective tubes according to DIN 43763 respectively according to specific S+S standards! damages caused by a fault in this device are excluded from warranty or liability.
  • Seite 10 Important notes S+S Regeltechnik GmbH hereby declares that the radio equipment type KFTF (20) - wModbus complies with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.spluss.de/120132CF1000029/ – This device may only be used in pollutant-free non-precipitating air.
  • Seite 11 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Capteur d’humidité et de température étalonnable pour montage en gaine HYGRASGARD ® KFTF - wModbus (± 2,0  %) ou KFTF 20 - wModbus (± 1,8  %), avec W-Modbus (Wireless), dans un boîtier plastique résistant aux chocs avec vis de fermeture rapide, au choix avec ⁄sans écran, avec filtre fritté...
  • Seite 12 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Schéma de raccordement HYGRASGARD ® Affectation des plots de connexion ® HYGRASGARD xx - wModbus xx - wModbus (M12) offset MALE DIP A 1 2 3 4 5 6 7 8 address Plug for display...
  • Seite 13 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Attention ! Il faut impérativement tenir compte des limites de sollici- Veillez à ne brancher l’appareil que sur un réseau de très basse tension tation mécaniques et thermiques des tubes de protection suivant de sécurité.
  • Seite 14 Généralités S+S Regeltechnik GmbH déclare par la présente que le système radio de type KFTF (20) - wModbus est conforme à la directive 2014/53/EU. Le texte complet de la déclaration UE de conformité est disponible à l‘adresse Internet suivante : www.spluss.de/120132CF1000029/ –...
  • Seite 15 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Калибруемый канальный датчик влажности и температуры HYGRASGARD ® KFTF - wModbus (± 2,0 %) или KFTF 20 - wModbus (± 1,8 %), с W-Modbus (Wireless), в ударопрочном пластиковом корпусе с быстрозаворачиваемыми винтами, на выбор с дисплеем или без дисплея, с...
  • Seite 16 ® HYGRASGARD KFTF (20) - wModbus Rev. Data - V42 Схема подключения HYGRASGARD ® Разводка контактов ® HYGRASGARD xx - wModbus xx - wModbus (M12) offset MALE DIP A 1 2 3 4 5 6 7 8 address Plug for display 1 2 3 4 pair...
  • Seite 17 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подклю- Внимание! В обязательном порядке следует учитывать предельные чение должно осуществляться исключительно к безопасно малому допустимые механические и термические нагрузки для защитных трубок согл. DIN 43763 либо специальных стандартов S+S ! напряжению.
  • Seite 18 Указания к продуктам Указания к продуктам Компания S+S Regeltechnik GmbH настоящим заявляет, что радиосистема типа KFTF (20) - wModbus соответствует Директиве 2014/53/EU. Полный текст декларации соответствия ЕС доступен по следующему интернет-адресу: www.spluss.de/120132CF1000029/ – Данный прибор допускается применять только в воздухе без конденсата и вредных веществ, при отсутствии пониженного или...
  • Seite 19 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Seite 20 D G U F r Busadresse, binärcodiert Bus address, binary coded Adresse du bus, code binaire Адресс шины, двоичный 0 0 0 0 0 0 0 1 0 0 1 1 0 0 1 1 0 1 1 0 0 1 0 1 1 0 0 1 0 1 1 1 1 1 0 0 1 0 0 1 0 0 0 0 0 0 1 0...

Diese Anleitung auch für:

Hygrasgard kftf 20