5
INSTALLATION
DANGER OF EYE DAMAGE!
Always set up and install all laser effects so that all laser light is at least
3 meters above the floor on which people can stand!
EMERGENCY SWITCH REQUIRED!
It must be possible to switch off the laser beam any time during operation to
avoid hazards in the event of failures, uncertain operating conditions or disturbance
within the audience. For this purpose, connect an emergency switch to the laser.
DANGER OF OVERHEATING!
The distance between the light output and the illuminated surface must be
More than 0.5 m. Always ensure sufficient ventilation.
The ambient temperature must always be below 45 °C.
CAUTION!
The use of controls, adjustments, or performance of procedures other than what
is specified herein may result in hazardous radiation exposure.
You can install the device on a truss system, on the wall, ceiling or floor. A mounting bracket and the
necessary screws are included in the package.
International laser safety regulations require that lasers must be operated in the fashion illustrated below,
with a minimum of 3 meters of vertical separation between the floor and the lowest laser light vertically.
Additionally, 2.5 meters of horizontal separation is required between laser light and audience or other public
spaces.
www.futurelight.com
30