9
Steam operation
9.1 Setting the desired time
You can set the time, after which the stove and the steam generator will turn on. You can set the time at a minimum of
15 minutes (display 00.15), or at a maximum of 23 hrs. and 45 minutes (display 23.45).
NOTE - Optional sauna door safety-monitor:
(refer to chapter 3):
1. Turn on the control according to chapter 5.1.
2. Press and hold time key A.
• The desired time is reset to zero and from thereon will count at 15 minute increments.
3. Release time key A.
• The display 3 indicates the desired time.
• The time set starts and the remaining time until the stove will start is indicated.
Steam operation at temperatures up to approx. 65°C only:
Refer to chapter 1 Operating Modes.
4. Using the knob 4 set the desired temperature at a range 5 of 40°- 65°C, and with the knob 7 set the desired steam
output.
Note (with a pencil mark) the settings most agreeable to you.
After the selected time has elapsed, the stove and steam generator start running. The steam output is implemented
by quickly turning on and off the steam generator. The time for turning the generator on and off depends on the steam
output selected.
• In display 3 the symbol for steam generator running will appear (see chapter 2).
5. Shut-off the operation of the steam generator:
see chapter 7 point 4.
9.2 Cancelling the selected time
1. Briefly press the time key A.
• The desired start-time will be cancelled.
10 Setting the fan
With the fan setting device 6 you can set the fan in the cabin at any operating mode, sauna or steam gene-
rator operation.
You can set the fan capacity from 00 - 100%.
1. Turn on the control according to chapter 5.1.
2. Set the desired fan capacity from 00-100% using the knob 6.
11 Automatic final cabin drying program
The final cabin drying program will start automatically as soon as steam generator operation has finished, and the cabin
will be dried.
NOTE - In regard to drying we recommend observing the instructions provided by the manufacturer.
As a general rule, the drying programme should not be prematurely ended since this could cause damage to the cabin (e.g. the formation of mould and rotting).
Program sequence:
1. The cabin is heated to 80°C,
the fan will run for 5 minutes with a capacity of 100%.
2. The temperature of 80°C is maintained,
the fan will run for 50 minutes with a capacity of 60% and then 10 minutes with a capacity of 100%.
3. The heater is switched off, the fan will run for 10 minutes with a capacity of 100%.
The control device will automatically switch off the heating system after expiration of the cabin drying programme.
For safety reasons, the appliance must then be disconnected from the mains by means of the ON/OFF switch 9.
WE DO IT FIRST.
Instructions for use for the user
Figure 6
at selected time
P. 13/20
EN