Calibration Function
The calibration function for the pump's maximum capacity is accessed by pressing the CAL key for at least 5
seconds.
Upon release of the key the display will shows:
Display
Pump Calibration
ENTER to START
Submenu Weekly Timer Display
PROG01
00.00
Display Advanced Submenu
Clock
Lun
Calibration
On
Flow
On
Password
0
*If two programs superimpose and one of them provides the activation, THE RELAY IS ACTIVATED
0000137176
MTWTFSS
-------
21:42
rev. 1.0
Settings
Press the Enter key to start the motor at 100%. The
display will show the dosing count in seconds:
Pump Calibration
345
sec
Press the Enter key again to stop the dosing and the
display will show:
Quantity?
190 cc
Press the UP and DOWN keys to enter the actual
dosed value. Press the Enter key to confirm and set
the pump calibration.
Settings
The programs can be scrolled through with the UP
and DOWN keys.
Parameter modifications can be accessed with the
Enter key:
PROG01
Time
Activation time (Time)
PROG01
Quantity
Quantity to dose
PROG01
Rel.Off
Relay management*:

Off: relay deactivated.

Before: the relay is activated before the
motor (time adjustment 0-999 sec.) and is
deactivated simultaneously.

After: the relay and the motor are activated
simultaneously, but deactivation of the motor
is delayed (time adjustment 0-999 sec.).
PROG01
Weekly
Weekly calendar
To change the parameters enable the modification
with the Enter key, choose the value with the UP and
DOWN keys and confirm with Enter.
Settings
With this item of the menu you can set the system
date and time. Change the settings by pressing the
Enter key and select the values using the UP and
DOWN keys. To confirm press Enter.
You can activate or deactivate the calibration
function.
You can activate or deactivate the Flow function.
The password can be modified with the UP and
DOWN keys, by choosing an incremental value
between 0 and 9999.
dos
hh.mm
00.00
0 cc
MTWTFSS
-x--x-x