following paragraphs. The paragraphs follow a chronological
order to facilitate installation.
Retrieve the documents (manuals and declarations of conformity)
and the components required to complete installation from
inside the unit.
Aermec accessories are supplied complete with a manual for
installation and use.
Aermec accessories are designed to be integrated into Aermec
units both for functional aspects and safety. Our units are designed
to be integrated with Aermec additional heating accessories
and if properly fitted they have no effect on the surrounding
environment, the technical spaces are unchanged with respect to
the basic unit.
Before installation, check the technical spaces required:
For installation;
For connection to the hydraulic circuits and to any valve;
For connection to the power supply;
For connection of an external panel flush to the unit (when
provided for);
For the setup of the flow and intake ducts (for models requiring it);
For correct and sufficient both intake and supply air flow,
For draining condensation;
For cleaning the filters;
For cleaning internal components and for maintenance.
WARNINGS ON USE
ATTENTION: The appliance can be used by children over the age
of 8 and by people with reduced physical, sensory or mental capabilities
or without experience or necessary knowledge, as long as they are
supervised or have been instructed on the safe use. Of the appliance
and on the understanding of the dangers inherent to it. Children must
not play with the appliance. The cleaning and maintenance to be
carried out by the user must not be carried out by children without
supervision.
DO NOT USE THE FAN COIL IMPROPERLY
The fan coil must not be used to breed, deliver and raise animals.
AIR OUT THE ROOM
Periodically air out the room in which the fan coil has been
installed; this is particularly important if the room is occupied by
many people, or if there are gas appliances or sources of odours.
ADJUST THE TEMPERATURE CORRECTLY
Ambient temperature should be regulated to ensure maximum
comfort, particularly for the elderly, infants and invalids. Prevent
temperature fluctuations between indoors and outdoors greater
than 7°C during summer. Excessively low temperatures during
summer involve higher electrical consumption.
DIRECT THE AIR FLOW CORRECTLY
Air delivered by the fan coil must not be directed onto people. Even
if the air temperature is higher than the ambient temperature, it
can cause a cold sensation and, therefore, discomfort.
DURING OPERATION
During operation, always leave the filter mounted on the fan coil;
otherwise the dust in the air will dirty the coil surface.
IT IS NORMAL
When in cooling mode, water vapour can come out of the fan coil
air flow.
When in heating mode, a slight hissing sound can be heard
near the fan coil. The fan coil may sometimes emit unpleasant
odours due to the accumulation of substances present in the
environment (clean the filter more often, especially if the room is
not aired out regularly).
During operation, noise and/or a creaking sound may be heard
from inside the device, due to the heat expansion of the elements
IFCZ-ACTALJ 2206 - C4696520_06
IT
EN
(plastic and metal). However, this does not mean there is a
malfunction and it does not damage the unit as long as the inlet
water temperature remains within the operating limits.