Fig. 1 B --- Overall dimensions SFH019P--- SFH097P
= air flow
Table 1 B
dimensions (mm)
Model
A
SFH019P*
370
SFH029P
400
SFH037P
460
550
SFH066P
SFH088P
570
SFH097P
660
* P = High pressure 40 barg
sed for connection shall be EN ISO 898-1 type 5.6 or 6.8. Bolts with an equivalent material yield and suitable for the specifi c pressure and
temperature application may be used instead.
SFH-P
3/8"BSPT
AIR
IN
1" BSPT
B
C
F
625
155
168.3
705
181
194
865
215
245
949
239
273
1035
275
324
1130
300
324
SFH-N/A/P / SFV-A
A
AIR
OUT
F
air in
air out
(D)
PN40 - DN65
PN40 - DN65
PN40 - DN80
PN40 - DN80
PN40 - DN100
PN40 - DN100
PN40 - DN125
PN40 - DN125
PN40 - DN150
PN40 - DN150
PN40 - DN200
PN40 - DN200
weight
volume
(E)
(kg)
(dm
24.5
30
53
62
98
151
pressure
2
)
(bar)
12.5
19
36.5
40
52
77.8
92.5
53