Herunterladen Diese Seite drucken

Technibel MAV 184 C Bedienungsanleitung Seite 7

Split system-klimagerät

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
HOW TO SET THE PRESENT TIME
1.
Press the PROGRAM button three times.
The time indication alone flashes.
2.
Press the HH button until the
present time hour is displayed.
Press the MM button until the
present time minutes are
displayed.
The display will automatically
stop flashing except for the
« : » symbol after 10 sec.
COOLING
NOTE
Verify that the main switch is in OFF position and
that the mode selector of the indoor unit is in ON
position.
1. Set the MODE selector to COOL
2. Press the ON/OFF button and switch the air
condioner ON.
3. Press the TEMP. buttons to set the desired
temperature (the temperature range is between
30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
4. Press the FAN SPEED selector button to the setting you want.
HEATING
COOL / DRY / HEAT Model Only
1. Set the MODE selector to HEAT
2. Press the ON/OFF button and switch the air condioner ON.
3. Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
4. Press FAN SPEED selector button to the setting you want.
CAUTION
For several minutes after the start of heating operation, the indoor fan
will run at a very low speed until the indoor heat exchanger coil has
warmed up sufficiently. This is because the COLD DRAFT
PREVENTION SYSTEM is operating. During this period, the
STANDBY lamp remains lit.
DEFROSTING OF HEAT EXCHANGER
OUTDOOR UNIT "STANDBY"
When the outdoor temperature is low, frost or ice
may appear on the heat exchanger coil, reducing
the heating performance. When this happens,
a microcomputer defrosting system operates.
At the same time, the fan in the indoor unit stops
and the STANDBY lamp remains lit until
defrosting is completed. Heating operation
restarts after several minutes. (This interval will
vary slightly depending on the room and outdoor
temperature).
ON I /OFF
NIGHT
OFF ON
MODE
SETBACK
CLOCK
1
FLAP
HH
TIMER
2
SELECT
FAN SPEED
MM
3
ACL
SELECT
TIME SET
BATTERIES
AIR CONDITIONER
1 HR.
TIMER
TEMP.
.
ON I /OFF
OFF ON
MODE
CLOCK
1
FLAP
HH
FAN SPEED
MM
4
SELECT
TIME SET
BATTERIES
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
*
OFF
TEST
OPR
STANDBY
STANDBY LAMP MAVxxx
STANDBY LAMP KPAxxx
HEATING PERFORMANCE
A heat pump conditioner heats a room by taking heat from outside
air. The heating efficiency will fall off when the outdoor temperature
is very low. If enough heat is not obtained with this air conditioner, use
another heating appliance in conjunction with it.
AUTOMATIC OPERATION
COOL / DRY / HEAT Model Only
A/C
1. Set the MODE selector to AUTO
SENSOR
2. Press the ON/OFF button and switch the air condioner ON.
3. Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED
TEMPERATURE.
When this setting is selected, the air conditioner calculates the
difference between the thermostat setting and the room temperature
3
and automatically switches to the COOL or HEAT mode as appropriate.
2
4. Press the FAN SPEED selector button to the setting you want.
NIGHT
SETBACK
TIMER
SELECT
ACL
A/C
OPERATION WITH THE REMOTE CONTROL UNIT
SENSOR
Example of operation diagram in the
temperature at 23°C.
27
A
26
25
B
24
C
23
C
22
21
B
20
A
19
NOTE
The air conditioner changes the operation mode (from cool to heat or vice
versa, if one of the following conditions occurs:
- ZONE A: changes if the difference between the room temperature and the
temperature set on the remote control unit is at least 3°C..
- ZONE B: changes if the difference between the room temperature and the
temperature set on the remote control unit is at least 1°C, one hour after
the compressor stop.
- ZONE C: never changes if the difference between the room temperature
and the temperature set on the remote control unit is no more than 1°C.
DEHUMIDIFYING (DRY)
1. Set the MODE selector switch to "DRY"
2. Press the ON/OFF button and switch the air condioner ON.
3. Press the TEMP. buttons to set the desired temperature (the
temperature range is between 30 °C max. and 16 °C min.).
THE DISPLAY SHOWS THE SELECTED TEMPERATURE.
ON
NOTE
TIMER
Use DRY operation when you want to reduce the humidity in the
room.
Once the room temperature reaches the set level, the unit repeats
the cycle of turning on and off automatically.
During DRY operation, the fan speed is automatically set to low or
very low and the fan stops every 20 and 10 seconds.
Dry operation is not possible if the indoor temperature is 15 °C or
less.
7
.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
(Auto) mode with the set room
D
D
1
H
1
ON
ON
MIN.
MAX.
COOL / DRY / HEAT Model Only
.
AFTER 5 SECONDS FROM THE REQUIRED
TEMPERATURE SETTING THE DISPLAY WILL
SHOW THE ROOM TEMPERATURE AGAIN.
EG
H
ON

Werbung

loading