Do not super extend and take care on a balanced position and secure footing to control the tool
also in unexpected situations.
Long hairs and loose clothing could tangled up in rotating parts of the device and cause serious
hurts.
Exemplary drawing.
Air supply requirements
Supply tool with a maximum pressure according to the technical data of this unit of clean, dry air.
Higher pressure drastically reduces tool life and/or can cause several injury.
Connect tool to air line using pipe, hose and fitting sizes shown in the diagram above.
Do not install a quick coupler directly into the air tool handle.
In order to have the tool working to full satisfaction the minimum air delivery must be at least 10%
higher than the indicated air consumption of the air tool.
Please consult the technical data in this instruction manual.
Pneumatic tool and safety instructions
The goal of Berner is to offer tools that help your work safely and efficiently.
The most important safety device for this or any tool is YOURSELF.
Your care and good judgment are the best protection against injury. All possible hazards cannot
be considered here, but we have tried to highlight some of the most important ones.
This tool may only used by qualified people.
This tool and its accessories must not be modified.
Do not lay down the device before all the rotary parts stopped.
Do not keep the air tool running while carrying it.
Maintain a firm grip on the power tool and position your body and arm to allow you to resist
kickback forces. Always use auxiliary handle, if provided, for maximum control over kickback or
torque reaction during start-up. The operator can control torque reactions or kickback forces, if
proper precautions are taken.
Never place your hand near the rotating accessory. Accessory may kickback over your hand.
Switch off the unit immediately in case of blocking or twist. Disconnect the air supply and do not
switch on again until the problem is solved. Understand the reason why the tool has been blocked
and make sure that this situation will not occur once more by counteract accordingly.
Air supply and connection hazards:
Air under pressure can cause several injury!
Always shut off air supply, drain hose of air pressure and disconnect tool from air supply, when
not in use, before changing accessories or maintenance.
Never put direct air at yourself or anyone else.
Whipping hoses can cause serious injury. Always check for damaged or loose hoses and fittings.
Do not exceed maximum air pressure according on the name plate respectively 6.3 bar.
Do not use quick disconnect couplings directly at the tool. See instructions for correct set-up !
EN