IU1012
5.1
Control elements
Item
in fig. 1, page 3
1
2
3
4
5
6
6
Mounting the IU0U automatic charger
6.1
Mounting instructions
If you wish to mount the IU0U automatic charger in a fixed position, please observe
the following mounting instructions:
• You can mount the IU0U automatic charger either horizontally or vertically.
• Do not mount the IU0U automatic charger
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions.
• The place of installation must be well-ventilated. A ventilation system must be
present for installations in small, closed spaces. The minimum clearance around
the IU0U automatic charger must be at least 25 cm (fig. 2, page 3).
• The air intake on the underside and the air outlet on the rear of the IU0U auto-
matic charger must be kept clear.
• For ambient temperatures higher than 40 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the IU0U automatic charger
under load can lead to the automatic shut-down.
• The installation surface must be level and sufficiently sturdy.
A
NOTICE!
Before drilling any holes, ensure that no electrical cables or other parts
of the vehicle can be damaged by drilling, sawing and filing.
EN
Explanation
Main switch
Mains connection
Cable with battery connection terminals
Fuse
Air outlet
Status LED
Mounting the IU0U automatic charger
11