Troubleshooting

Problem
Tool operating slowly
Tool seized
Strong vibrations when tool is switched on
Tool will not stop after trigger is fully
released
8
Possible Cause
Pressure incorrect
Dirt within the mechanism
Air blockage
Air leak
Blockage in gauze mesh filter
Dirt or rust in mechanism
Dirt or rust in mechanism
Dirt or rust in mechanism
Cutting disc fitted incorrectly
Cutting disc damaged (cracks, deformations or splinters)
Flange damaged (burred or notched)
Spindle bent
Throttle valve O-ring or valve seat damaged
If the above troubleshooting solutions fail, contact your dealer or an authorised Silverline service centre.
Solution
Set the correct air pressure according to the specification
Pour oil into air inlet as per maintenance instructions
Operate tool in short bursts to clear blockage
Check all fittings and hose for air leaks and correct issue by re-tightening, using PTFE
tape or replacing
Remove Quick Connector (10) and clean mesh filter
Try 'Tool operating slowly' solutions
Tap tool gently with a soft mallet
Free mechanism by rotating drive manually when disconnected from air line
Remove disc, inspect for damage and refit
Replace cutting disc
Replace flange
Have the tool repaired by an authorised Silverline service centre
Have the tool repaired at an authorised Silverline service centre