Warning!
seat leaks caused by the minimum pilot pressure being too
low (on cfb and cfi) or the medium pressure being too high!
▶ Observe the minimum control pressure and medium pressure
(see "6.4.2 Pressure ranges").
9
mainTenance Work
→
Complete a visual inspection of the equipment once a year. Shorter
maintenance intervals may be recommended depending on the
operating conditions.
9.1
replacement parts
Caution!
risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable replacement parts may
cause injuries and damage the device and the surrounding area.
▶ Use only original accessories and original replacement parts
from Bürkert.
wearing parts: Seals and the swivel plate
→
In the event of a leak, replace the relevant wear part.
The maintenance and repair instructions are available on the
Internet:
www.burkert.com
All manuals and user guides at all-guides.com
Type 2100
Removal
10
removal
Danger!
risk of injury from discharge of medium and pressure!
It is dangerous to remove a device which is under pressure due to
the sudden release of pressure or discharge of medium.
▶ Before removing a device, switch off the pressure and vent the lines.
procedure:
→
Loosen the pneumatic connection.
→
Remove the device.